PLASTICS
PIPING SYSTEM FOR WATER SUPPLY
|
Unplasticized poly (vinyl chloride) (PVC-U) pipes for:
for
the supply of water under pressure at approximately 20° C (cold
water) The
pipes are manufactured in compliance with EN 1452-2 standard of CEN
(European commitee for standardizarion). The
manufacturer's Quality System is in compliance with ISO 9002 standard
and certified by IIP CISQ certificate n° 217 IQNet certificate n°
IT 3407
|
Dimensions and weights EN 1452-2
| Series PN 6 | Series PN 7,5 | Series PN 10 | Series PN 12,5 | Series PN 16 | Series PN 20 | ||||||||
|
Outside
diameter
|
Thickness
sp
|
Weight
kg/m
|
Thickness
sp
|
Weight
kg/m
|
Thickness
sp
|
Weight
kg/m
|
Thickness
sp
|
Weight
kg/m
|
Thickness
sp
|
Weight
kg/m
|
Thickness
sp
|
Weight
kg/m
|
Outside
diameter
|
|
63
|
1.9
|
0.578
|
2.0
|
0.608
|
3.0
|
0.878
|
3.8
|
1.112
|
4.7
|
1.334
|
5.8
|
1.646
|
63
|
|
75
|
2.2
|
0.804
|
2.3
|
0.841
|
3.6
|
1.254
|
4.5
|
1.568
|
5.6
|
1.871
|
6.8
|
2.272
|
75
|
|
90
|
2.7
|
1.163
|
2.8
|
1.206
|
4.3
|
1.797
|
5.4
|
2.257
|
6.7
|
2.68
|
8.2
|
3.28
|
90
|
|
110
|
2.7
|
1.426
|
3.2
|
1.690
|
4.2
|
2.134
|
5.3
|
2.693
|
6.6
|
3.228
|
8.1
|
3.961
|
110
|
|
125
|
3.1
|
1.839
|
3.7
|
2.195
|
4.8
|
2.753
|
6.0
|
3.441
|
7.4
|
4.107
|
9.2
|
5.106
|
125
|
|
140
|
3.5
|
2.337
|
4.1
|
2.738
|
5.4
|
3.472
|
6.7
|
4.308
|
8.3
|
5.153
|
10.3
|
6.395
|
140
|
|
160
|
4.0
|
3.024
|
4.7
|
3.553
|
6.2
|
4.549
|
7.7
|
5.65
|
9.5
|
6.723
|
11.8
|
8.351
|
160
|
|
180
|
4.4
|
3.750
|
5.3
|
4.517
|
6.9
|
5.702
|
8.6
|
7.107
|
10.7
|
8.538
|
13.3
|
10.612
|
180
|
|
200
|
4.9
|
4.613
|
5.9
|
5.554
|
7.7
|
7.063
|
9.6
|
8.806
|
11.9
|
10.532
|
14.7
|
13.01
|
200
|
|
225
|
5.5
|
5.832
|
6.6
|
6.998
|
8.6
|
8.861
|
10.8
|
11.128
|
13.4
|
13.37
|
16.6
|
16.563
|
225
|
|
250
|
6.2
|
7.370
|
7.3
|
8.677
|
9.6
|
11.007
|
11.9
|
13.644
|
14.8
|
16.186
|
18.4
|
20.123
|
250
|
|
280
|
6.9
|
9.143
|
8.2
|
10.866
|
10.7
|
13.787
|
13.4
|
17.266
|
280
|
||||
|
315
|
7.7
|
11.487
|
9.2
|
13.725
|
12.1
|
17.537
|
15.0
|
21.74
|
315
|
||||
|
355
|
8.7
|
14.649
|
10.4
|
17.511
|
13.6
|
22.291
|
16.9
|
27.7
|
355
|
||||
|
400
|
9.8
|
18.612
|
11.7
|
22.221
|
15.3
|
27.648
|
19.1
|
34.515
|
400
|
||||
|
500
|
12.3
|
29.389
|
14.6
|
34.885
|
500
|
||||||||
General Characteristics of PVC-U Pipes
| General characteristics | ||
|
Marking
|
PLAST
MEC PVC EN 1452-2 PN__ U PVC-U manufacturing date
|
|
| Uses | ||
|
Domestic
water supply of drinking water for human consumption - Industrial and
agricultural water supply
|
||
| Chemical resistance | ||
|
The PVC-U pipe doesnt contain vinyl chloride monomer (VCM) exceeding 1 ppm when determined by means of gas-phase chromatography using the headspace method according to ISO 6401.
|
||
| Appearance | ||
|
The
internal and external surface of pipes are smooth, clean and free from
scoring, cavities and other surface defects.
|
||
| Mechanical characteristics of pipes | ||
|
Impact resistance
|
TIR ≤ 10 %
|
EN 744
|
| Physical characteristics of pipes | ||
|
Vicat
softening temperature
|
³
80°C
|
EN
727
|
| Performance requirements | ||
|
Elastomeric lip sealing ring
|
EN 681-1
|
|
| Laying conditions | ||
|
The
PVC pipes do not need to be re-enforced and covered with concrete except
in particular cases. In normal installation conditions, the expected
average deflection of the outside diameter of the pipes will be less
than 8 %.
|
||